MIST HUMIDIFICATION SYSTEMS for

Air cooling and humidification

 

Working Principle – Filtered water is passed through special nozzles at a pressure of 100-150 atmospheric pressures by specially designed high pressure pump. The water molecule gets vaporized into microscopic droplets with dia of 5-20 micron size. The droplets are very small enough to hover by themselves and vaporize very fast, creating various physical effects like cooling, rapid increase in humidity etc

 

 ADVANTAGES OF MIST HUMIDIFICATION SYSTEM OVER     AIR WASHER SYSTEM

1)      Consumes only 30% power when compared  to conventional air washer system

2)      Costs only 50% of the air washer system- a complete system for an area of 10000 sq ft will cost around 2 lakhs only when compared to nearly 5 lakhs for a air washer system

3)      Localized very accurate humidity can be achieved with this system

4)      No separate plant room is required – Hence saving in building cost

Application

 1) Yarn storage rooms – We can maintain 80% RH in the yarn storage area continuously irrespective of out side temperature and thus help the yarns regain 6-8% moisture content lost during processing and thus increasing the final weight and higher profit without any extra expenditure

2) We can maintain very accurate control of humidity in the areas where the machines are concentrated in various departments like spinning / weaving / Ginning / knitting to improve the production and quality

3) Air cooling of offices / conference halls etc at ¼ the cost of air conditioning

 

Some of the mills where the above system is working satisfactorily are

1)      PRICOT mills, Palaghat

2)      Premier mills . Hosur

3)      Sangeeth Textiles , Coimbatore

4)      Siva Tex yarn , Dindigul

5)      Rajapalayam mills, Rajapalayam

 

 Air cooling

The following tables give the cooling effect achieved by mist cooling system

 B.T.U.'s removed from the air based on a given amount of water consumed / hour        :

 6 litres.................17,400 B.T.U.'s removed
 9 litres................26,100 B.T.U.'s removed
12 litres................34,800 B.T.U.'s removed
15 litres................43,500 B.T.U.'s removed

 

 

 

THE PAY BACK PERIOD – You can recover the cost of installation in a few months it self from the increased production and saving in the power bill

 

 

 